PROCEDURE
INSTALL HEATED OXYGEN SENSOR
| *a | Length of SST 30 mm (1.18 in.) |
| *b | Length of Torque Wrench 260 mm (10.2 in.) |
Using SST, install the heated oxygen sensor to the front exhaust pipe assembly.
Note
If the heated oxygen sensor has been struck or dropped, replace it.
Tech Tips
This torque value is effective when SST is parallel to the torque wrench.
The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).
The "with SST" torque value is effective when using a torque wrench with a fulcrum length of 260 mm (10.2 in.).
If using a torque wrench with a different length, or connecting the torque wrench and SST at an angle, refer to the alternate torque values.
Engage the 3 wire harness clamps.
Connect the heated oxygen sensor connector.
INSTALL FRONT FLOOR COVER LH
INSPECT FOR EXHAUST GAS LEAK
PERFORM INITIALIZATION
Perform "Inspection After Repair" after replacing the heated oxygen sensor.