ECM INSTALLATION

PROCEDURE


  1. INSTALL NO. 2 ECM BRACKET


    1. Install the No. 2 ECM bracket to the ECM with the 2 screws.

      Torque:
      3.0 N*m  { 31 kgf*cm, 27 in.*lbf }
  2. INSTALL ECM BRACKET


    1. Install the ECM bracket to the ECM with the 2 screws.

      Torque:
      3.0 N*m  { 31 kgf*cm, 27 in.*lbf }
  3. INSTALL ECM


    1. Install the ECM with the 3 bolts.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }

      Note

      If the ECM has been struck or dropped, replace it.

    2. Engage the wire harness clamp.

    3. A002BDD

      Connect the 2 ECM connectors and lower the 2 levers.

      Note


      • When connecting the ECM connectors, make sure that dirt, water or other foreign matter does not contact the connecting parts of the ECM connectors.

      • Be sure to securely connect the ECM connectors.

  4. INSTALL AIR CLEANER ASSEMBLY


    1. Engage the clamp to set the air cleaner assembly.

    2. Install the air cleaner assembly to the inlet air cleaner assembly.

    3. Install the air cleaner assembly to the No. 1 air cleaner hose and tighten the hose clamp.

    4. Install the 2 bolts to the air cleaner assembly.

      Torque:
      5.0 N*m  { 51 kgf*cm, 44 in.*lbf }
    5. Connect the mass air flow meter sub-assembly connector and engage the wire harness clamp.

  5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  6. PERFORM INITIALIZATION

    Click here