2GR-FE COOLING SERVICE DATA

THERMOSTAT
Condition Specified Condition
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 10 mm (0.394 in.) or more at 95°C (203°F)
COOLING FAN MOTOR
Item Motor Type Condition Specified Condition
Cooling fan motor for 200 W Type Battery voltage applied at 20°C (68°F) 26.0 to 32.0 A
No. 2 cooling fan motor for 200 W Type 26.0 to 32.0 A
COOLING FAN RELAY
Tester Connection Tester Connection Specified Condition
3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω
RADIATOR
Item Condition Specified Condition
Radiator cap

Standard value

(for brand-new cap)

93 to 123 kPa (0.9 to 1.3 kgf/cm2, 13.5 to 17.8 psi)

Minimum standard value

(for used cap)

79 kPa (0.8 kgf/cm2, 11.5 psi)

COOLANT
Capacity Classification
11.2 liters (11.8 US qts, 9.9 Imp.qts) Use only "TOYOTA Super Long Life Coolant", or similar high qualitye thylene glycol based non-silicate, non-amine, non-nitrite, and non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of low phosphates and organic acids).