1AR-FE COOLING TORQUE SPECIFICATIONS

Water pump
Part Tightened N*m kgf*cm ft.*lbf
Water pump x Water inlet housing
21 N*m
214 kgf*cm
15 ft.*lbf
Thermostat
Part Tightened N*m kgf*cm ft.*lbf
Water inlet x Water inlet housing
10 N*m
102 kgf*cm
7 ft.*lbf
Cooling fan motor
Part Tightened N*m kgf*cm in.*lbf
Fan shroud x cooling fan motor
2.6 N*m
27 kgf*cm
23 in.*lbf
Fan shroud x No. 2 cooling fan motor
2.6 N*m
27 kgf*cm
23 in.*lbf
Fan x Cooling fan motor
6.3 N*m
64 kgf*cm
56 in.*lbf
No. 2 Fan x No. 2 cooling fan motor
6.3 N*m
64 kgf*cm
56 in.*lbf