| Condition | Specified Condition |
|---|---|
| Standard valve opening temperature | 80 to 84°C (176 to 183°F) |
| Standard valve lift | 10 mm (0.394 in.) or more at 95°C (203°F) |
| Item | Condition | Specified Condition |
|---|---|---|
| Cooling fan motor | Battery voltage applied at 20°C (68°F) | 13.6 to 19.6 A |
| No. 2 cooling fan motor | Battery voltage applied at 20°C (68°F) | 13.6 to 19.6 A |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| Item | Condition | Specified Condition |
|---|---|---|
| Radiator cap | Standard value (for brand-new cap) | 93 to 123 kPa (0.9 to 1.3 kgf/cm2, 13.5 to 18.0 psi) |
| Minimum standard value (for used cap) | 79 kPa (0.8 kgf/cm2, 11.5 psi) |
| Capacity | Classification |
|---|---|
| 9.2 liters (9.7 US qts, 8.1 Imp.qts) | Use only "TOYOTA Super Long Life Coolant", or similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, and non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of low phosphates and organic acids). |