RELAY ON-VEHICLE INSPECTION

PROCEDURE


  1. INSPECT H-LP LH RELAY


    1. A00229VC03
      *a

      Component without harness connected

      (H-LP LH Relay)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the H-LP LH relay.

  2. INSPECT H-LP RH RELAY


    1. A00229VC03
      *a

      Component without harness connected

      (H-LP RH Relay)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the H-LP RH relay.