STOP LIGHT SWITCH INSTALLATION

PROCEDURE


  1. INSTALL STOP LIGHT SWITCH ASSEMBLY


    1. A0022EYC01
      *a Stop Light Switch Lock Nut

      Temporarily install the stop light switch assembly with the stop light switch lock nut as shown in the illustration.

    2. A0021MJC04
      *1 Stop Light Switch Assembly
      *a Cushion
      *b Stop Light Switch Lock Nut

      Turn the stop light switch assembly so that the clearance between the end of the threads and cushion is within A.

      Part Measurement
      A 0.87 to 2.4 mm (0.0343 to 0.0945 in.)
    3. Tighten the stop light switch lock nut.

      Torque:
      17 N*m  { 173 kgf*cm, 13 ft.*lbf }
    4. Connect the connector.

  2. INSTALL NO. 1 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY

    Click here