AUTOMATIC HIGH BEAM MAIN SWITCH INSPECTION

PROCEDURE


  1. INSPECT AUTO HIGH BEAM SWITCH


    1. A011O4KC09
      *a

      Component without harness connected

      (Auto High Beam Switch)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (+B) - 1 (E) Auto high beam switch off 10 kΩ or higher
      Auto high beam switch on Below 1 Ω

      If the result is not as specified, replace the auto high beam switch.

    2. Illumination Inspection


      1. Apply auxiliary battery voltage to the auto high beam switch and check that the switch illuminates.

        OK
        Condition Specified Condition

        Auxiliary battery positive (+) → Terminal 3 (ILL+)

        Auxiliary battery negative (-) → Terminal 2 (ILL-)

        Illuminates

        If the result is not as specified, replace the auto high beam switch.