RELAY ON-VEHICLE INSPECTION

PROCEDURE


  1. INSPECT WIP RELAY


    1. A011MHAN01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 4 Voltage is not applied between terminals 1 and 2 Below 1 Ω
      Voltage is applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage is not applied between terminals 1 and 2 10 kΩ or higher
      Voltage is applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the WIP relay.

  2. INSPECT INT RELAY


    1. A011MHAN01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 4 Voltage is not applied between terminals 1 and 2 Below 1 Ω
      Voltage is applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage is not applied between terminals 1 and 2 10 kΩ or higher
      Voltage is applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the INT relay.