METER / GAUGE SYSTEM Entire Combination Meter does not Operate

DESCRIPTION

This circuit is the power source circuit for the combination meter assembly. This circuit provides two types of power sources; one is a constant power source, and the other is an IG power source.

WIRING DIAGRAM

A0022LDE09

CAUTION / NOTICE / HINT

Note

Inspect the fuses of circuits related to this system before performing the following procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)


    1. Disconnect the K3 combination meter assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      K3-31 (ES) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      K3-21 (IG+) - Body ground Power switch off Below 1 V
      Power switch on (IG) 11 to 14 V
      K3-22 (B) - Body ground Power switch off 11 to 14 V
      Result
      Proceed to
      OK
      NG

    OK
    NG