METER / GAUGE SYSTEM Meter Illumination is Always Dark

DESCRIPTION

The combination meter assembly receives signals from this circuit to adjust the illumination of the combination meter assembly. The combination meter assembly sets the illumination level based on the user operation of the light control rheostat switch.

WIRING DIAGRAM

B003XR5E86
*1 Main Body ECU (Multiplex Network Body ECU)
*2 CAN Communication Line
*3 Combination Meter Assembly (Meter Circuit Plate)

CAUTION / NOTICE / HINT

Tech Tips


  • The meter illumination dims when the taillights are turned on.

  • Setting the meter illumination to maximum brightness cancels the above dimming of the meter illumination.

  • Setting the meter illumination to minimum brightness turns off the meter illumination.

  • Before starting the following inspection, check if lighting system DTCs are output.

    Click here

PROCEDURE


  1. CHECK CAN COMMUNICATION SYSTEM


    1. Check if CAN communication DTCs are output.

      Click here

      Result
      Result Proceed to
      CAN communication DTCs are not output. A
      CAN communication DTCs are output. B

    B
    A
  2. READ VALUE USING GTS (LIGHT SENSOR ILLUMINANCE)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Main Body / Data List.

    5. Check the values by referring to the table below.


      Body Electrical > Main Body > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Light Sensor Illuminance Light sensor illuminance 0 lx to 8191 lx Value output according to ambient light levels -

      Body Electrical > Main Body > Data List
      Tester Display
      Light Sensor Illuminance
      Result
      Result Proceed to
      The output value changes according to the ambient light level. A
      The output value does not change according to the ambient light level. B

    B
    A
  3. REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)


    1. Replace the main body ECU (multiplex network body ECU) with a new or known good one.

      Click here

      OK
      The operation of the combination meter assembly returns to normal.
      Result
      Proceed to
      OK
      NG

    OK
    NG