PERSONAL LIGHT INSPECTION

PROCEDURE


  1. INSPECT MAP LIGHT ASSEMBLY


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      S3-4 (+B1) - S4-14 (RIFR) Always Below 1 Ω
      S4-10 (RLMP) - S4-20 (GND9) Always Below 1 Ω
      S3-1 (IG) - S3-14 (IG2) Always Below 1 Ω
      S3-19 (GND) - S3-2 (GND2) Always Below 1 Ω

      If the result is not as specified, replace the map light assembly.

    2. A01MTILC23
      *A w/ Intrusion Sensor Cancel Switch
      *a

      Component without harness connected

      (Map Light Assembly)

      Inspect the front map light.


      1. Apply auxiliary battery voltage to the connector and check that the front map light comes on.

        OK
        Measurement Condition Condition Specified Condition

        Auxiliary battery positive (+) → S3-4 (+B1)

        Auxiliary battery negative (-) → S4-20 (GND9)

        Front map light switch LH on Front map light LH comes on
        Front map light switch RH on Front map light RH comes on

        Auxiliary battery positive (+) → S3-5 (+B5)

        Auxiliary battery negative (-) → S4-20 (GND9)

        Front map light switch LH on Front map light LH comes on
        Front map light switch RH on Front map light RH comes on

        If the result is not as specified, replace the bulb or map light assembly.

    3. Inspect the front dome light.


      1. Apply auxiliary battery voltage to the connector and check that the front dome light comes on.

        OK
        Measurement Condition Condition Specified Condition

        Auxiliary battery positive (+) → S3-4 (+B1)

        Auxiliary battery negative (-) → S3-9 (CTY)

        Always Front dome light comes on

        Auxiliary battery positive (+) → S3-4 (+B1)

        Auxiliary battery negative (-) → S3-10 (RIFL)

        Auxiliary battery positive (+) → S3-5 (+B5)

        Auxiliary battery negative (-) → S3-9 (CTY)

        Auxiliary battery positive (+) → S3-5 (+B5)

        Auxiliary battery negative (-) → S3-10 (RIFL)

        If the result is not as specified, replace the bulb or map light assembly.

    4. Inspect the front dome light switch and door switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        S4-19 (CILL) - S3-19 (GND) Front dome light switch on Below 1 Ω
        S4-19 (CILL) - S3-19 (GND) Front dome light switch off 10 kΩ or higher
        S4-18 (DOOR) - S3-19 (GND) Door switch on Below 1 Ω
        S4-18 (DOOR) - S3-19 (GND) Door switch off 10 kΩ or higher

        If the result is not as specified, replace the map light assembly.

    5. Inspect the switch illumination.


      1. Apply auxiliary battery voltage to the connector and check that the switch illumination comes on.

        OK
        Measurement Condition Condition Specified Condition

        Auxiliary battery positive (+) → S3-16 (ILLB)

        Auxiliary battery negative (-) → S3-8 (LILL)

        Always Switch illumination comes on

        If the result is not as specified, replace the map light assembly.

    6. Inspect the intrusion sensor cancel switch. (w/ Intrusion Sensor Cancel Switch)


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        S3-22 (SOFF) - S3-19 (GND) Intrusion sensor cancel switch pushed and held Below 1 Ω
        S3-22 (SOFF) - S3-19 (GND) Intrusion sensor cancel switch not pushed 10 kΩ or higher

        If the result is not as specified, replace the map light assembly.