LIN COMMUNICATION SYSTEM, Diagnostic DTC:B1206

DTC Code DTC Name
B1206 P/W Master Switch Communication Stop

DESCRIPTION

This DTC is stored when LIN communication between the multiplex network master switch assembly and main body ECU (multiplex network body ECU) stops for 10 seconds or more.

DTC No. Detection Item DTC Detection Condition Trouble Area
B1206 P/W Master Switch Communication Stop No communication between multiplex network master switch assembly and main body ECU (multiplex network body ECU) for 10 seconds or more.
  • Multiplex network master switch assembly

  • Main body ECU (multiplex network body ECU)

  • Instrument panel junction block assembly

  • Wire harness or connector

  • P/W fuse

WIRING DIAGRAM

A01MRK9E33
A011MQWE34

CAUTION / NOTICE / HINT

Note


  • Inspect the fuses for circuits related to this system before performing the following procedure.

  • If the main body ECU (multiplex network body ECU) is replaced, refer to Service Bulletin.

PROCEDURE


  1. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


    1. Remove the instrument panel junction block assembly.

      Click here

      A011LZ0C04
      *a

      Component without harness connected

      (Instrument Panel Junction Block Assembly)

      - -
    2. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.

    3. Measure the resistance according to the value(s) in the table below.

      Tech Tips

      This inspection is to check the LIN communication line in the instrument panel junction block assembly that connects the wire harness to the built-in main body ECU (multiplex network body ECU).

      Standard Resistance
      Tester Connection Condition Specified Condition
      4B-21 - MB-16 (LIN2) Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY)


    1. for LHD


      1. Disconnect the N27*1 or N18*2 multiplex network master switch assembly connector.


        • *1: w/o Seat Position Memory System

        • *2: w/ Seat Position Memory System

      2. Measure the resistance according to the value(s) in the table below.

        Note

        Make sure that each ECU is in sleep mode before performing the inspection. To enter sleep mode, turn the power switch from on (IG) to off and wait for 60 seconds or more without operating any switches.

        Standard Resistance
        Tester Connection Condition Specified Condition
        4B-21 - N27-7 (LIN1)*1 Power switch off Below 1 Ω
        4B-21 - N18-17 (LIN1)*2 Power switch off Below 1 Ω
        N27-7 (LIN1) - Body ground*1 Power switch off 10 kΩ or higher
        N18-17 (LIN1) - Body ground*2 Power switch off 10 kΩ or higher
        4B-21 - Body ground Power switch off 10 kΩ or higher

        • *1: w/o Seat Position Memory System

        • *2: w/ Seat Position Memory System

    2. for RHD


      1. Disconnect the N12*1 or N3*2 multiplex network master switch assembly connector.


        • *1: w/o Seat Position Memory System

        • *2: w/ Seat Position Memory System

      2. Measure the resistance according to the value(s) in the table below.

        Note

        Make sure that each ECU is in sleep mode before performing the inspection. To enter sleep mode, turn the power switch from on (IG) to off and wait for 60 seconds or more without operating any switches.

        Standard Resistance
        Tester Connection Condition Specified Condition
        4B-21 - N12-7 (LIN1)*1 Power switch off Below 1 Ω
        4B-21 - N3-17 (LIN1)*2 Power switch off Below 1 Ω
        N12-7 (LIN1) - Body ground*1 Power switch off 10 kΩ or higher
        N3-17 (LIN1) - Body ground*2 Power switch off 10 kΩ or higher
        4B-21 - Body ground Power switch off 10 kΩ or higher

        • *1: w/o Seat Position Memory System

        • *2: w/ Seat Position Memory System

      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY - AUXILIARY BATTERY, BODY GROUND)


    1. for LHD


      1. Measure the voltage according to the value(s) in the table below.

        Standard Voltage
        Tester Connection Condition Specified Condition
        N27-21 (B) - N27-17 (GND)*1 Power switch off 11 to 14 V
        N18-11 (B) - N18-12 (GND)*2 Power switch off 11 to 14 V

        • *1: w/o Seat Position Memory System

        • *2: w/ Seat Position Memory System

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        N27-17 (GND) - Body ground*1 Always Below 1 Ω
        N18-12 (GND) - Body ground*2 Always Below 1 Ω

        • *1: w/o Seat Position Memory System

        • *2: w/ Seat Position Memory System

    2. for RHD


      1. Measure the voltage according to the value(s) in the table below.

        Standard Voltage
        Tester Connection Condition Specified Condition
        N12-21 (B) - N12-17 (GND)*1 Power switch off 11 to 14 V
        N3-11 (B) - N3-12 (GND)*2 Power switch off 11 to 14 V

        • *1: w/o Seat Position Memory System

        • *2: w/ Seat Position Memory System

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        N12-17 (GND) - Body ground*1 Always Below 1 Ω
        N3-12 (GND) - Body ground*2 Always Below 1 Ω

        • *1: w/o Seat Position Memory System

        • *2: w/ Seat Position Memory System

      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY


    1. Replace the multiplex network master switch assembly.

      Click here

      Result
      Proceed to
      NEXT

    NEXT
  5. CHECK DTC OUTPUT


    1. Clear the DTCs.

      Click here


      Body Electrical > Main Body > Clear DTCs
    2. Recheck for DTCs.


      Body Electrical > Main Body > Trouble Codes
      OK
      DTC B1206 is not output.
      Result
      Proceed to
      OK
      NG

    OK
    NG