DESCRIPTION
Power is supplied to the remote operation board illumination when the light control switch is in the tail or head position.
Tech Tips
Only the "AUDIO", "MENU" and return switches on the remote operation board illuminate.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Note
Inspect the fuses for circuits related to this system before performing the following procedure.
PROCEDURE
CHECK HARNESS AND CONNECTOR (ILLUMINATION SIGNAL)
Disconnect the K79 remote operation board connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (REMOTE OPERATION BOARD - COMBINATION METER ASSEMBLY)
Disconnect the K79 remote operation board connector.
Disconnect the K3 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE REMOTE OPERATION BOARD
Replace the remote operation board.
Check if the switch illumination turns on.
| OK |
|---|
| The switch illumination turns on when the light control switch is in the tail or head position. |
| Result | |||
|---|---|---|---|
|
| OK |
|
END |
| NG |
|
GO TO METER / GAUGE SYSTEM Click here |