ELECTRONICALLY CONTROLLED BRAKE SYSTEM Slip Indicator Light does not Come ON

DESCRIPTION

The skid control ECU assembly is connected to the combination meter assembly via CAN communication.

CAUTION / NOTICE / HINT

Note

When replacing the skid control ECU assembly, perform initialization and calibration of the linear solenoid valve.

Click here

PROCEDURE


  1. CHECK CAN COMMUNICATION SYSTEM


    1. Check if CAN communication system DTCs are output.

      Click here

      Result
      Result Proceed to
      DTCs are not output. A
      DTCs are output. B

    B
    A
  2. PERFORM ACTIVE TEST USING GTS (SLIP INDICATOR LIGHT)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Select the Active Test on the GTS.

      Click here


      Chassis > ABS/VSC/TRC > Active Test
      Tester Display Measurement Item Control Range Diagnostic Note
      Slip Indicator Light Slip indicator light Indicator light ON/OFF Observe combination meter assembly

      Chassis > ABS/VSC/TRC > Active Test
      Tester Display
      Slip Indicator Light
    4. Select the Data List on the GTS.

      Click here


      Chassis > ABS/VSC/TRC > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Slip Indicator Light Slip indicator light ON or OFF

      ON: Indicator light on

      OFF: Indicator light off

      -

      Chassis > ABS/VSC/TRC > Data List
      Tester Display
      Slip Indicator Light
    5. Check the operating condition of the slip indicator light when operating it using the GTS.

      Result
      Result Proceed to
      Slip indicator light in the Data List does not change using the Active Test. A
      Slip indicator light in the Data List turns ON/OFF using the Active Test. B

      Tech Tips

      If troubleshooting has been carried out according to Problem Symptoms Table, refer back to the table and proceed to the next step before replacing the parts.

      Click here


    A
    B
  3. INSPECT COMBINATION METER ASSEMBLY


    1. Turn the power switch off.

    2. Perform the Active Test of the combination meter assembly (meter CPU) using the GTS.

      Click here


      Body Electrical > Combination Meter > Active Test
      Tester Display
      Indicat. Lamp Slip
    3. Check the combination meter assembly.

      OK
      The slip indicator light turns on or off in accordance with GTS operation.

      Tech Tips

      If troubleshooting has been carried out according to Problem Symptoms Table, refer back to the table and proceed to the next step.

      Click here

      Result
      Proceed to
      OK
      NG

    OK
    NG