ABSORBER CONTROL ACTUATOR(for Front Side) INSPECTION

PROCEDURE


  1. INSPECT ABSORBER CONTROL ACTUATOR


    1. A011OR0C03
      *A for LH
      *B for RH
      *a

      Component without harness connected

      (Absorber Control Actuator)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LH
      Tester Connection Condition Specified Condition
      1 (FBL+) - 3 (E FL) Always 12.0 to 12.8 Ω
      2 (FAL+) - 3 (E FL) Always 12.0 to 12.8 Ω
      4 (FBL-) - 3 (E FL) Always 12.0 to 12.8 Ω
      5 (FAL-) - 3 (E FL) Always 12.0 to 12.8 Ω
      for RH
      Tester Connection Condition Specified Condition
      1 (FBR+) - 3 (E FR) Always 12.0 to 12.8 Ω
      2 (FAR+) - 3 (E FR) Always 12.0 to 12.8 Ω
      4 (FBR-) - 3 (E FR) Always 12.0 to 12.8 Ω
      5 (FAR-) - 3 (E FR) Always 12.0 to 12.8 Ω
    2. Check absorber control actuator operation.