PROCEDURE
INSPECT FRONT ACCELERATION SENSOR LH
Connect 3 1.5 V dry cell batteries in series.
Connect a positive (+) lead from the batteries to terminal 3 (SGB) and a negative (-) lead to terminal 2 (SGG).
| *a | Component without harness connected (Front Acceleration Sensor LH) |
|
Top |
|
Bottom |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Note
Do not apply a voltage of more than 6 V.
Do not drop the front acceleration sensor. If it is dropped, replace it with a new one.
Never place the front acceleration sensor upside down.
Tech Tips
When the acceleration sensor is tilted, it may output a different value.