SHIFT LEVER POSITION SENSOR INSPECTION

PROCEDURE


  1. INSPECT SHIFT LEVER POSITION SENSOR


    1. A011NI3C03
      *a

      Component without harness connected

      (Shift Lever Position Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition

      7 (+B) - 1 (P)

      7 (+B) - 4 (MJ)

      Shift lever in P Below 1 Ω

      7 (+B) - 3 (D)

      7 (+B) - 5 (R)

      7 (+B) - 9 (FD)

      7 (+B) - 6 (RV)

      10 kΩ or higher
      7 (+B) - 2 (N) 4.2 to 5.2 kΩ

      7 (+B) - 5 (R)

      7 (+B) - 4 (MJ)

      7 (+B) - 6 (RV)

      Shift lever in R Below 1 Ω

      7 (+B) - 3 (D)

      7 (+B) - 1 (P)

      7 (+B) - 9 (FD)

      10 kΩ or higher
      7 (+B) - 2 (N) 4.2 to 5.2 kΩ

      7 (+B) - 2 (N)

      7 (+B) - 4 (MJ)

      Shift lever in N Below 1 Ω

      7 (+B) - 3 (D)

      7 (+B) - 1 (P)

      7 (+B) - 5 (R)

      7 (+B) - 9 (FD)

      7 (+B) - 6 (RV)

      10 kΩ or higher

      7 (+B) - 3 (D)

      7 (+B) - 9 (FD)

      7 (+B) - 4 (MJ)

      Shift lever in D Below 1 Ω

      7 (+B) - 1 (P)

      7 (+B) - 5 (R)

      7 (+B) - 6 (RV)

      10 kΩ or higher
      7 (+B) - 2 (N) 4.2 to 5.2 kΩ

      If the resistance value is not as specified, replace the shift lever position sensor.