POWER SWITCH INSPECTION

Click here
Click here

PROCEDURE


  1. Click here

    INSPECT POWER SWITCH


    1. A011ON6C03
      *a

      Component without harness connected

      (Power Switch)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition

      5 (SS1) - 6 (AGND)

      1 (SS2) - 6 (AGND)

      Not pushed 10 kΩ or higher
      Pushed Below 1 Ω

      If the result is not as specified, replace the power switch.

    2. Apply auxiliary battery voltage between the terminals of the power switch, and check the illumination condition of the power switch.

      OK
      Condition Specified Condition

      Auxiliary battery positive (+) → Terminal 9 (SWIL)

      Auxiliary battery negative (-) → Terminal 6 (AGND)

      Illuminates
      Tip:
      • If the positive (+) auxiliary battery lead and negative (-) auxiliary battery lead are incorrectly connected, the power switch indicator light will not illuminate.

      • If the voltage is too low, the power switch indicator light will not illuminate.

      If the result is not as specified, replace the power switch.