PROCEDURE
REMOVE COOL AIR INTAKE DUCT SEAL
REMOVE INLET NO. 1 AIR CLEANER
REMOVE ENGINE UNDER COVER
DRAIN COOLANT (for Inverter)
REMOVE INVERTER WATER PUMP ASSEMBLY
| *1 | Inlet Hybrid Water Pump Hose |
| *2 | Outlet No. 1 Hybrid Water Pump Hose |
Slide the 2 clips and disconnect the inlet hybrid water pump hose and outlet No. 1 hybrid water pump hose.
Note
Put pieces of cloth into the pipes and disconnected hoses or cover the pipes and hoses with plastic bags to prevent foreign matter from entering the inverter water pump assembly and cooling system.
Disconnect the inverter water pump assembly connector.
Note
Apply insulating tape to the connectors of the wire harness and inverter water pump assembly to prevent the entry of coolant.
Remove the 3 bolts and inverter water pump assembly from the HV water pump bracket sub-assembly.
REMOVE HV WATER PUMP BRACKET SUB-ASSEMBLY
Tech Tips
Perform this procedure only when replacement of the HV water pump bracket sub-assembly is necessary.
Remove the air cleaner assembly with No. 2 air cleaner hose.
Disengage the 3 clamps from the HV water pump bracket sub-assembly.
Remove the 2 bolts and HV water pump bracket sub-assembly.