HYBRID BATTERY SYSTEM TERMINALS OF ECU

A01MSLDC06
*1 Battery Voltage Sensor - -

Terminal No.

(Symbols)

Wiring Color Terminal Description Condition Specified Condition
z13-1 (TC0) - z13-11 (GC0) G - G Intake air temperature sensor HV battery temperature: -40 to 90°C (-40 to 194°F) 4.8 (-40°C (-40°F)) to 1.0 (90°C (194°F))
z13-5 (TB2) - z13-15 (GB2) L - L Battery temperature sensor 2 HV battery temperature: -40 to 90°C (-40 to 194°F) 4.8 (-40°C (-40°F)) to 1.0 (90°C (194°F))
z13-6 (TB1) - z13-16 (GB1) W - W Battery temperature sensor 1 HV battery temperature: -40 to 90°C (-40 to 194°F) 4.8 (-40°C (-40°F)) to 1.0 (90°C (194°F))
z13-7 (TB0) - z13-17 (GB0) R - R Battery temperature sensor 0 HV battery temperature: -40 to 90°C (-40 to 194°F) 4.8 (-40°C (-40°F)) to 1.0 (90°C (194°F))
z13-9 (IB) - z13-20 (GIB) Y - B Current sensor Power switch on (READY) 0.5 to 4.5 V
z13-10 (VIB) - z13-20 (GIB) BR - B Power source for battery current sensor Power switch on (IG) 4.5 to 5.5 V
k1-1 (IGCT) - k1-5 (GND) L - W-B Control signal Power switch on (READY) 11 to 14 V
k1-2 (BTH+) - k1-5 (GND) R - W-B Serial communication Power switch on (IG)

Pulse generation

(waveform 1)

k1-3 (BTH-) - k1-5 (GND) G - W-B Serial communication Power switch on (IG)

Pulse generation

(waveform 2)

k1-8 (FP) - k1-5 (GND) Y-R - W-B Battery cooling blower No. 0 monitor signal Cooling blower stopped 4.5 to 5.5 V
Cooling blower activated

Pulse generation

(waveform 3)

k1-5 (GND) - Body ground W-B Ground Always (continuity check) Below 1 Ω

  1. Oscilloscope waveforms

    Tech Tips

    Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


    1. A01MRP5N02

      Waveform 1

      Item Content
      Terminal k1-2 (BTH+) - k1-5 (GND)
      Equipment Setting 2 V/DIV., 500 μs/DIV.
      Condition Power switch on (IG)

      Tech Tips

      The waveform will vary depending on the content of the digital communication (digital signal).

    2. A01MS0HN02

      Waveform 2

      Item Content
      Terminal k1-3 (BTH-) - k1-5 (GND)
      Equipment Setting 2 V/DIV., 500 μs/DIV.
      Condition Power switch on (IG)

      Tech Tips

      The waveform will vary depending on the content of the digital communication (digital signal).

    3. A01MTVHN02

      Waveform 3

      Item Content
      Terminal k1-8 (FP) - k1-5 (GND)
      Equipment Setting 5 V/DIV., 1 ms/DIV.
      Condition Battery cooling blower assembly operating (Active Test of cooling fan being performed)

      Tech Tips

      The frequency of the waveform will vary with the operating speed of the battery cooling blower assembly.