PROCEDURE
INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH
| *a | Component without harness connected (Power Window Regulator Motor Assembly LH) |
| *b | Clockwise |
| *c | Counterclockwise |
Apply positive (+) auxiliary battery voltage to connector terminal 2 (B).
Note
Do not apply positive (+) auxiliary battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
Connect a negative (-) auxiliary battery to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).
Check that the motor gear rotates smoothly as follows:
| OK | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the power window regulator motor assembly LH.
Note
Initialize the power window control system after installing the power window regulator motor and regulator assembly.
INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
| *a | Component without harness connected (Power Window Regulator Motor Assembly RH) |
| *b | Clockwise |
| *c | Counterclockwise |
Apply positive (+) auxiliary battery voltage to connector terminal 2 (B).
Note
Do not apply positive (+) auxiliary battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
Connect a negative (-) auxiliary battery to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).
Check that the motor gear rotates smoothly as follows:
| OK | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the power window regulator motor assembly RH.
Note
Initialize the power window control system after installing the power window regulator motor and regulator assembly.