POWER WINDOW REGULATOR MOTOR(for Front Door) INSPECTION

PROCEDURE


  1. INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH


    1. A01MTAVC10
      *a

      Component without harness connected

      (Power Window Regulator Motor Assembly LH)

      *b Clockwise
      *c Counterclockwise

      Apply positive (+) auxiliary battery voltage to connector terminal 2 (B).

      Note

      Do not apply positive (+) auxiliary battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.

    2. Connect a negative (-) auxiliary battery to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).

    3. Check that the motor gear rotates smoothly as follows:

      OK
      Measurement Condition Specified Condition

      1. Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 10 (UP).

      3. Disconnect and reconnect the negative (-) auxiliary battery lead for terminal 10 (UP) within 1 second.

      Motor gear rotates clockwise

      1. Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 7 (DOWN).

      3. Disconnect and reconnect the negative (-) auxiliary battery lead for terminal 7 (DOWN) within 1 second.

      Motor gear rotates counterclockwise

      • If the result is not as specified, replace the power window regulator motor assembly LH.

      Note

      Initialize the power window control system after installing the power window regulator motor and regulator assembly.

  2. INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH


    1. A01MRQYC09
      *a

      Component without harness connected

      (Power Window Regulator Motor Assembly RH)

      *b Clockwise
      *c Counterclockwise

      Apply positive (+) auxiliary battery voltage to connector terminal 2 (B).

      Note

      Do not apply positive (+) auxiliary battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.

    2. Connect a negative (-) auxiliary battery to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).

    3. Check that the motor gear rotates smoothly as follows:

      OK
      Measurement Condition Specified Condition

      1. Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 10 (UP).

      3. Disconnect and reconnect the negative (-) auxiliary battery lead for terminal 10 (UP) within 1 second.

      Motor gear rotates counterclockwise

      1. Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 7 (DOWN).

      3. Disconnect and reconnect the negative (-) auxiliary battery lead for terminal 7 (DOWN) within 1 second.

      Motor gear rotates clockwise

      • If the result is not as specified, replace the power window regulator motor assembly RH.

      Note