AIR CONDITIONING SYSTEM, Diagnostic DTC:B1443/43

DTC Code DTC Name
B1443/43 Air Outlet Damper Control Servo Motor Circuit

DESCRIPTION

The No. 3 air conditioning radiator damper servo sub-assembly sends pulse signals to inform the air conditioning amplifier assembly of the damper position. The air conditioning amplifier assembly activates the motor (normal or reverse) based on these signals to move the No. 3 air conditioning radiator damper servo sub-assembly to the appropriate position, which controls the air outlet switching.

The air conditioning amplifier assembly communicates with the servo through a communication/driver IC and wiring assembly called the air conditioning harness assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1443/43 Air Outlet Damper Control Servo Motor Circuit Air outlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 3 air conditioning radiator damper servo sub-assembly
  • No. 3 air conditioning radiator damper servo sub-assembly

  • Air conditioning harness assembly

  • Air conditioning amplifier assembly

Memorized

(30 sec. or more)*1


WIRING DIAGRAM

B003YGGE13

CAUTION / NOTICE / HINT

Tech Tips

Confirm that no mechanical problem is present because this DTC can be output when either a damper link or damper is mechanically locked.

PROCEDURE


  1. READ VALUE USING GTS


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Operate the mode switch.

    5. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    6. Check the value(s) by referring to the table below.


      Body Electrical > Air Conditioner > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Air Outlet Servo Pulse (D) No. 3 air conditioning radiator damper servo sub-assembly target pulse

      Min.: 128

      Max.: 383


      • FACE1: 245 (pulse)

      • FACE2: 254 (pulse)

      • FACE: 230 (pulse)

      • B/L: 217 (pulse)

      • B/L2: 209 (pulse)

      • FOOT-0 (for save energy and airflow control function): 183 (pulse)

      • FOOT-0 (except save energy and airflow control function): 199 (pulse)

      • FOOT-D: 199 (pulse)

      • FOOT-R (for save energy and airflow control function): 183 (pulse)

      • FOOT-R (except save energy and airflow control function): 199 (pulse)

      • FOOT-F (manual mode and for save energy and airflow control function): 183 (pulse)

      • FOOT-F (manual mode and except save energy and airflow control function): 199 (pulse)

      • FOOT-F (automatic mode): 183 (pulse)

      • FOOT/DEF: 168 (pulse)

      • DEF: 140 (pulse)

      -
      Air Outlet Servo Actu Pulse(D) No. 3 air conditioning radiator damper servo sub-assembly actual pulse

      Min.: 128

      Max.: 383


      • FACE1: 245 (pulse)

      • FACE2: 254 (pulse)

      • FACE: 230 (pulse)

      • B/L: 217 (pulse)

      • B/L2: 209 (pulse)

      • FOOT-0 (for save energy and airflow control function): 183 (pulse)

      • FOOT-0 (except save energy and airflow control function): 199 (pulse)

      • FOOT-D: 199 (pulse)

      • FOOT-R (for save energy and airflow control function): 183 (pulse)

      • FOOT-R (except save energy and airflow control function): 199 (pulse)

      • FOOT-F (manual mode and for save energy and airflow control function): 183 (pulse)

      • FOOT-F (manual mode and except save energy and airflow control function): 199 (pulse)

      • FOOT-F (automatic mode): 183 (pulse)

      • FOOT/DEF: 168 (pulse)

      • DEF: 140 (pulse)

      -

      Body Electrical > Air Conditioner > Data List
      Tester Display
      Air Outlet Servo Pulse (D)
      Air Outlet Servo Actu Pulse(D)
      OK
      When the mode switch is operated, the actual pulse changes following the target pulse.
      Result
      Result Proceed to
      Target pulse changes but actual pulse does not change A
      Target pulse and actual pulse do not change B
      Actual pulse changes following the target pulse (When troubleshooting according to the DTC) C
      Actual pulse changes following the target pulse (When troubleshooting according to Problem Symptoms Table) D

    B
    C
    D
    A
  2. REPLACE NO. 3 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY


    1. Replace the No. 3 air conditioning radiator damper servo sub-assembly.

      Click here

      Tech Tips

      Since the servo motor cannot be inspected while it is removed from the vehicle, replace the servo motor with a new or known good one and check that the condition returns to normal.

    2. Check for DTCs.

      Click here


      Body Electrical > Air Conditioner > Trouble Codes
      Result
      Result Proceed to
      DTC B1443/43 is output A
      DTC B1443/43 is not output B

    B
    A
  3. REPLACE AIR CONDITIONING HARNESS ASSEMBLY


    1. Replace the air conditioning harness assembly.

      Click here

      Tech Tips

      Since the air conditioning harness assembly cannot be inspected while it is removed from the vehicle, replace the air conditioning harness assembly with a new or known good one and check that the condition returns to normal.

    2. Check for DTCs.

      Click here


      Body Electrical > Air Conditioner > Trouble Codes
      Result
      Result Proceed to
      DTC B1443/43 is output A
      DTC B1443/43 is not output B

    A
    B
  4. RECONFIRM DTC OUTPUT


    1. Check for DTCs.

      Click here


      Body Electrical > Air Conditioner > Trouble Codes
      Result
      Result Proceed to
      DTC B1443/43 is output A
      DTC B1443/43 is not output B

    A
    B