AIR CONDITIONING SYSTEM DATA LIST / ACTIVE TEST


  1. DATA LIST

    Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    Note

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    5. Check the value(s) by referring to the table below.


      Body Electrical > Air Conditioner > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Room Temperature Sensor Cooler (room temp. sensor) thermistor

      Min.: -6.50°C (20.30°F)

      Max.: 57.25°C (135.05°F)

      Actual cabin temperature displayed -
      Ambient Temp Sensor Thermistor assembly

      Min.: -23.30°C (-9.94°F)

      Max.: 65.95°C (150.71°F)

      Actual ambient temperature displayed -
      Adjusted Ambient Temp Adjusted ambient temperature

      Min.: -30.80°C (-23.44°F)

      Max.: 50.80°C (123.44°F)

      - -
      Evaporator Fin Thermistor No. 1 cooler thermistor

      Min.: -29.70°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual evaporator temperature displayed -
      Evaporator Target Temp Evaporator target temperature

      Min.: -327.68°C (-557.82°F)

      Max.: 327.67°C (621.81°F)

      Evaporator target temperature displayed -
      Solar Sensor (D Side) Driver side automatic light control sensor*2 or automatic light control sensor*3

      Min.: 0

      Max.: 255

      Driver side automatic light control sensor*2 or automatic light control sensor*3 value increases as brightness increases -
      Solar Sensor (P Side) Front passenger side automatic light control sensor

      Min.: 0

      Max.: 255

      Front passenger side automatic light control sensor value increases as brightness increases *2
      Engine Coolant Temp Engine coolant temperature sensor

      Min.: 1.30°C (34.34°F)

      Max.: 90.55°C (194.99°F)

      Actual engine coolant temperature displayed -
      Blower Motor Speed Level Blower motor speed level

      Min.: 0

      Max.: 31

      Displayed speed level increases in range between 0 and 31 as blower motor speed increases -
      Regulator Pressure Sensor Air conditioner pressure sensor

      Min.: -456.6 kPaG

      Max.: 3294.3 kPaG

      Actual refrigerant pressure displayed -
      Air Outlet Servo Pulse (R) No. 6 air conditioning radiator damper servo sub-assembly target pulse

      Min.: 128

      Max.: 383


      • FACE1: 242 (pulse)

      • FACE2: 245 (pulse)

      • FACE: 242 (pulse)

      • B/L1: 284 (pulse)

      • B/L: 284 (pulse)

      • B/L2: 303 (pulse)

      • FOOT: 303 (pulse)

      • FOOT/DEF: 333 (pulse)

      • DEF: 353 (pulse)

      *2
      Air Outlet Servo Actual Pls(R) No. 6 air conditioning radiator damper servo sub-assembly actual pulse

      Min.: 128

      Max.: 383


      • FACE1: 242 (pulse)

      • FACE2: 245 (pulse)

      • FACE: 242 (pulse)

      • B/L1: 284 (pulse)

      • B/L: 284 (pulse)

      • B/L2: 303 (pulse)

      • FOOT: 303 (pulse)

      • FOOT/DEF: 333 (pulse)

      • DEF: 353 (pulse)

      *2
      Air Mix Servo Targ Pulse(D) No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) target pulse

      Min.: 128

      Max.: 383


        for LHD:

      • MAX. COLD: 254 (pulse)

      • MAX. HOT: 360 (pulse)


        for RHD:

      • MAX. COLD: 258 (pulse)

      • MAX. HOT: 152 (pulse)

      -
      Air Mix Servo Actual Pulse(D) No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) actual pulse

      Min.: 128

      Max.: 383


        for LHD:

      • MAX. COLD: 254 (pulse)

      • MAX. HOT: 360 (pulse)


        for RHD:

      • MAX. COLD: 258 (pulse)

      • MAX. HOT: 152 (pulse)

      -
      Air Mix Servo Targ Pulse(P) No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) target pulse

      Min.: 128

      Max.: 383


        for LHD:

      • MAX. COLD: 258 (pulse)

      • MAX. HOT: 152 (pulse)


        for RHD:

      • MAX. COLD: 254 (pulse)

      • MAX. HOT: 360 (pulse)

      -
      Air Mix Servo Actual Pulse(P) No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) actual pulse

      Min.: 128

      Max.: 383


        for LHD:

      • MAX. COLD: 258 (pulse)

      • MAX. HOT: 152 (pulse)


        for RHD:

      • MAX. COLD: 254 (pulse)

      • MAX. HOT: 360 (pulse)

      -
      Air Outlet Servo Pulse (D) No. 3 air conditioning radiator damper servo sub-assembly target pulse

      Min.: 128

      Max.: 383


      • FACE1: 245 (pulse)

      • FACE2: 254 (pulse)

      • FACE: 230 (pulse)

      • B/L: 217 (pulse)

      • B/L2: 209 (pulse)

      • FOOT-0 (for save energy and airflow control function): 183 (pulse)

      • FOOT-0 (except save energy and airflow control function): 199 (pulse)

      • FOOT-D: 199 (pulse)

      • FOOT-R (for save energy and airflow control function): 183 (pulse)

      • FOOT-R (except save energy and airflow control function): 199 (pulse)

      • FOOT-F (manual mode and for save energy and airflow control function): 183 (pulse)

      • FOOT-F (manual mode and except save energy and airflow control function): 199 (pulse)

      • FOOT-F (automatic mode): 183 (pulse)

      • FOOT/DEF: 168 (pulse)

      • DEF: 140 (pulse)

      -
      Air Outlet Servo Actu Pulse(D) No. 3 air conditioning radiator damper servo sub-assembly actual pulse

      Min.: 128

      Max.: 383


      • FACE1: 245 (pulse)

      • FACE2: 254 (pulse)

      • FACE: 230 (pulse)

      • B/L: 217 (pulse)

      • B/L2: 209 (pulse)

      • FOOT-0 (for save energy and airflow control function): 183 (pulse)

      • FOOT-0 (except save energy and airflow control function): 199 (pulse)

      • FOOT-D: 199 (pulse)

      • FOOT-R (for save energy and airflow control function): 183 (pulse)

      • FOOT-R (except save energy and airflow control function): 199 (pulse)

      • FOOT-F (manual mode and for save energy and airflow control function): 183 (pulse)

      • FOOT-F (manual mode and except save energy and airflow control function): 199 (pulse)

      • FOOT-F (automatic mode): 183 (pulse)

      • FOOT/DEF: 168 (pulse)

      • DEF: 140 (pulse)

      -
      Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly target pulse

      Min.: 128

      Max.: 383


        for LHD:

      • Recirculation: 238 (pulse)

      • Fresh: 206 (pulse)


        for RHD:

      • Recirculation: 274 (pulse)

      • Fresh: 306 (pulse)

      -
      Air Inlet Damper Actual Pulse No. 1 blower damper servo sub-assembly actual pulse

      Min.: 128

      Max.: 383


        for LHD:

      • Recirculation: 238 (pulse)

      • Fresh: 206 (pulse)


        for RHD:

      • Recirculation: 274 (pulse)

      • Fresh: 306 (pulse)

      -
      Electric Heater Count Maximum electric heater operation level

      Min.: 0

      Max.: 2

      Maximum possible operation of electric heater displayed *1
      Electric Heater Active Level Actual electric heater operation level

      Min.: 0

      Max.: 2

      Actual operation level of electric heater displayed *1
      Compressor Speed Compressor speed

      Min.: 0 rpm

      Max.: 65535 rpm

      Actual compressor rotation speed displayed -
      Compressor Target Speed Compressor target speed

      Min.: 0 rpm

      Max.: 65535 rpm

      Compressor target rotation speed displayed -
      Shift Set Temperature Shift set temperature 2C decr, 1C decr, Normal, 1C incr, 2C incr Customized value displayed -
      Air Inlet Mode Air inlet mode Auto or Manual Customized value displayed -
      Compressor Mode Compressor mode Auto or Manual Customized value displayed -
      Add Foot Air in FACE Mode Add foot air in face mode ON or OFF Customized value displayed -
      Noise and Vibration Reduction Noise and vibration reduction OFF or ON Customized value displayed -
      ECO MODE Cancel ECO drive mode cancel OFF or ON Customized value displayed -
      ECO Switch Combination switch assembly (ECO mode switch) OFF or ON

      ON: Combination switch assembly (ECO mode switch) being turned and held at ECO position

      OFF: Combination switch assembly (ECO mode switch) not turned

      -
      Refrigerant Shortage Check Refrigerant shortage check ON or OFF Customized value displayed -
      Fan speed increment control Fan speed increment control Slow, Normal, Fast Customized value displayed -
      Foot/DEF Auto Mode Foot/defroster auto mode ON or OFF Customized value displayed -
      Foot/DEF Auto Blow Up Foot/defroster auto blower speed increase ON or OFF Customized value displayed -
      Ambient Temperature Shift Ambient temperature shift 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr Customized value displayed -
      COOL A/M Servo Targ Pls(D) No. 5 air conditioning radiator damper servo sub-assembly (driver side lower air mix)*4 or No. 4 air conditioning radiator damper servo sub-assembly (driver side lower air mix)*5 target pulse

      Min.: 128

      Max.: 383


      • MAX. COLD: 254 (pulse)

      • MAX. HOT: 360 (pulse)

      -
      COOL A/M Servo Actual Pulse(D) No. 5 air conditioning radiator damper servo sub-assembly (driver side lower air mix)*4 or No. 4 air conditioning radiator damper servo sub-assembly (driver side lower air mix)*5 actual pulse

      Min.: 128

      Max.: 383


      • MAX. COLD: 254 (pulse)

      • MAX. HOT: 360 (pulse)

      -
      COOL A/M Servo Targ Pls(P) No. 4 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix)*4 or No. 5 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix)*5 target pulse

      Min.: 128

      Max.: 383


      • MAX. COLD: 254 (pulse)

      • MAX. HOT: 360 (pulse)

      -
      COOL A/M Servo Actual Pulse(P) No. 4 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix)*4 or No. 5 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix)*5 actual pulse

      Min.: 128

      Max.: 383


      • MAX. COLD: 254 (pulse)

      • MAX. HOT: 360 (pulse)

      -
      A/O Damper DEF Pos(D Side) No. 1 air conditioning radiator damper servo sub-assembly target pulse

      Min.: 128

      Max.: 383


      • FACE1: 164 (pulse)

      • FACE2: 164 (pulse)

      • FACE: 164 (pulse)

      • B/L (manual mode): 164 (pulse)

      • B/L (automatic mode): 164 to 180 (pulse)

      • B/L2: 164 (pulse)

      • FOOT-D: 230 (pulse)

      • FOOT-R: 176 (pulse)

      • FOOT (manual mode): 176 (pulse)

      • FOOT (automatic mode): 176 to 186 (pulse)

      • FOOT/DEF: 270 (pulse)

      • DEF: 270 (pulse)

      -
      A/O Damper DEF Actual Pos(D) No. 1 air conditioning radiator damper servo sub-assembly actual pulse

      Min.: 128

      Max.: 383


      • FACE1: 164 (pulse)

      • FACE2: 164 (pulse)

      • FACE: 164 (pulse)

      • B/L (manual mode): 164 (pulse)

      • B/L (automatic mode): 164 to 180 (pulse)

      • B/L2: 164 (pulse)

      • FOOT-D: 230 (pulse)

      • FOOT-R: 176 (pulse)

      • FOOT (manual mode): 176 (pulse)

      • FOOT (automatic mode): 176 to 186 (pulse)

      • FOOT/DEF: 270 (pulse)

      • DEF: 270 (pulse)

      -
      Compressor Drive Check Compressor drive check OK or NG

      NG: Compressor does not drive

      OK: Compressor drives

      -
      Set Temperature (D Side) Driver side set temperature*2 or set temperature*3

      Min.: MAX COLD

      Max.: MAX HOT

      Driver side set temperature*2 or set temperature*3 displayed -
      Set Temperature (P Side) Front passenger side set temperature

      Min.: MAX COLD

      Max.: MAX HOT

      Front passenger side set temperature displayed *2
      Operation Limitation Control History Count (Level1) History of auxiliary battery voltage drop in the past

      Min.: 0

      Max.: 255

      Number of times auxiliary battery voltage dropped in the past displayed

      Counted when voltage drops below the specified level due to over discharge while driving.

      Tech Tips

      Clear control history after check

      Operation Limitation Control History Count (Level2) History of auxiliary battery voltage drop in the past

      Min.: 0

      Max.: 255

      Number of times auxiliary battery voltage dropped in the past displayed

      Counted if voltage drops from the level when Operation Limitation Control History Count (Level1) is counted.

      Tech Tips

      Clear control history after check

      Number of Trouble Codes Number of trouble codes

      Min.: 0

      Max.: 255

      Number of DTCs displayed -

      • *1: w/ PTC Heater

      • *2: for Dual Type

      • *3: for Single Type

      • *4: for LHD

      • *5: for RHD

  2. ACTIVE TEST

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. Check the operation by referring to the table below.


      Body Electrical > Air Conditioner > Active Test
      Tester Display Measurement Item Control Range Diagnostic Note
      Blower Motor Blower motor with fan sub-assembly Min.: 0, Max.: 31 -
      Compressor Target Speed Compressor with motor assembly Min.: 0, Max.: 7500 -
      Defogger Relay (Rear) Rear window defogger OFF, ON -
      Deicer Relay (Front) Windshield deicer OFF, ON *2
      Heater Active Level Quick heater assembly Min.: 0, Max.: 2 *1
      Air Mix Servo Targ Pulse(D) No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) pulse

      Min.: 128

      Max.: 383

      for LHD:


      • Operates between 254 to 360 pulses

      for RHD:


      • Operates between 152 to 258 pulses

      Air Mix Servo Targ Pulse(P) No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) pulse

      Min.: 128

      Max.: 383

      for LHD:


      • Operates between 152 to 258 pulses

      for RHD:


      • Operates between 254 to 360 pulses

      Air Outlet Servo Pulse (D) No. 3 air conditioning radiator damper servo sub-assembly pulse

      Min.: 128

      Max.: 383

      Operates between 140 to 254 pulses
      Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly pulse

      Min.: 128

      Max.: 383

      for LHD:


      • Operates between 206 to 238 pulses

      for RHD:


      • Operates between 274 to 306 pulses

      Cool A/M Servo Pulse(D) No. 5 air conditioning radiator damper servo sub-assembly (driver side lower air mix)*3 or No. 4 air conditioning radiator damper servo sub-assembly (driver side lower air mix)*4 pulse

      Min.: 128

      Max.: 383

      Operates between 254 to 360 pulses
      Cool A/M Servo Pulse(P) No. 4 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix)*3 or No. 5 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix)*4 pulse

      Min.: 128

      Max.: 383

      Operates between 254 to 360 pulses
      A/O Servo Pulse(Rr D) No. 6 air conditioning radiator damper servo sub-assembly pulse

      Min.: 128

      Max.: 383

      Operates between 242 to 353 pulses

      *5

      DEF A/O Servo Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly pulse

      Min.: 128

      Max.: 383

      Operates between 164 to 270 pulses

      • *1: w/ PTC Heater

      • *2: w/ Windshield Deicer System

      • *3: for LHD

      • *4: for RHD

      • *5: for Dual Type