AIR CONDITIONING AMPLIFIER ASSEMBLY
Tech Tips
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Terminal No. (Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| K10-1 (GND) - Body ground | BR - Body ground | Ground for main power supply | Always | Below 1 V |
| K10-3 (BLW) - K10-1 (GND) | BE - BR | Blower motor speed control signal |
|
Pulse generation (See waveform 1) |
| K10-5 (IG+) - K10-1 (GND) | R - BR | Power source (IG) | Power switch on (IG) | 11 to 14 V |
| Power switch off | Below 1 V | |||
| K10-6 (+B1) - K10-1 (GND) | L - BR | Power source (Back-up) | Power switch off | 11 to 14 V |
| K10-8 (PTC1) - K10-1 (GND)*1 | R - BR | Quick heater assembly operation signal |
|
Below 1 V |
|
11 to 14 V | |||
| K10-21 (RLIN) - K10-1 (GND) | P - BR | LIN communication signal | Power switch on (IG) | Pulse generation |
| K10-23 (IDH) - K10-1 (GND) | B - BR | Inverter with converter assembly current over signal |
|
Below 1 V |
|
4.75 to 5.25 V | |||
| K10-26 (PTC2) - K10-1 (GND)*1 | L - BR | Quick heater assembly operation signal |
|
Below 1 V |
|
11 to 14 V | |||
| K10-29 (ECOS) - K10-1 (GND) | GR - BR | Combination switch assembly (ECO mode switch) signal |
|
11 to 14 V |
|
Below 1 V | |||
| K11-1 (SG-1) - Body ground | W - Body ground | Ground for cooler (room temp. sensor) thermistor | Always | Below 1 V |
| K11-3 (CANH) - K11-4 (CANL) | P - B | CAN communication system | CAN communication is performed | Pulse generation |
| K11-9 (PRE) - K11-32 (SG-2) | W - G | Air conditioner pressure sensor signal |
|
4.71 V or higher |
|
Below 0.74 V | |||
|
0.74 to 4.71 V | |||
| K11-10 (TAM) - K11-32 (SG-2) | V - G | Thermistor assembly signal |
|
1.35 to 1.75 V |
|
0.9 to 1.2 V | |||
| K11-13 (S5-3) - K11-32 (SG-2) | B - G | Power supply for air conditioner pressure sensor | Power switch on (IG) | 4.75 to 5.25 V |
| Power switch off | Below 1 V | |||
| K11-16 (TR) - K11-1 (SG-1) | B - W | Cooler (room temp. sensor) thermistor signal |
|
1.8 to 2.2 V |
|
1.2 to 1.6 V | |||
| K11-32 (SG-2) - Body ground | G - Body ground | Ground for air conditioner pressure sensor, thermistor assembly | Always | Below 1 V |
| z1-1 (BUS G) - Body ground | - | Ground for BUS IC | Always | Below 1 V |
| z1-2 (BUS) - z1-1 (BUS G) | - | BUS IC control signal | Power switch on (IG) | Pulse generation |
| z1-3 (B BUS) - z1-1 (BUS G) | - | Power supply for BUS IC | Power switch off | 11 to 14 V |
| z1-11 (TEA) - z1-12 (SGA) | - | No. 1 cooler thermistor signal |
|
2.0 to 2.4 V |
|
1.4 to 1.8 V | |||
| z1-12 (SGA) - Body ground | - | Ground for No. 1 cooler thermistor | Always | Below 1 V |
*1: w/ PTC Heater
Waveform 1:
| Item | Content |
|---|---|
| Terminal No. | K10-3 (BLW) - K10-1 (GND) |
| Tool Setting | 1 V/DIV., 500 μs/DIV. |
| Vehicle Condition |
|
AIR CONDITIONING CONTROL ASSEMBLY
Tech Tips
Check from the rear of the connector while it is connected to the air conditioning control assembly.
| Terminal No. (Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| K65-6 (LIN1) - Body ground | P - Body ground | LIN communication signal | Power switch on (IG) | Pulse generation |
| K65-8 (IG+) - K65-14 (GND) | P - W-B | Power source (IG) | Power switch off | Below 1 V |
| Power switch on (IG) | 11 to 14 V | |||
| K65-14 (GND) - Body ground | W-B - Body ground | Ground for air conditioning control assembly | Always | Below 1 V |
| K65-15 (ILL-) - Body ground | BE - Body ground | Illumination signal | Light control switch off | Below 1 V |
| Light control switch in tail or head position | Pulse generation | |||
| K65-16 (ILL+) - Body ground | G - Body ground | Illumination signal | Light control switch off | Below 1 V |
| Light control switch in tail or head position | 11 to 14 V |