AIR CONDITIONING SYSTEM IG Power Source Circuit

DESCRIPTION

Power source voltage is supplied to the air conditioning amplifier assembly when the power switch is turned on (IG). This power is used for operating the air conditioning amplifier assembly, servo motors, etc.

WIRING DIAGRAM

A01MRTDE71

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - IG POWER SOURCE)


    1. Disconnect the K10 air conditioning amplifier assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      K10-5 (IG+) - Body ground Power switch off Below 1 V
      K10-5 (IG+) - Body ground Power switch on (IG) 11 to 14 V
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      K10-1 (GND) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG