LUMBAR SWITCH INSPECTION

PROCEDURE


  1. INSPECT FRONT LUMBAR POWER SEAT SWITCH


    1. A011Q7NC02
      *a
      • Hold Switch (for LHD)

      • Release Switch (for RHD)

      *b
      • Release Switch (for LHD)

      • Hold Switch (for RHD)

      *c

      Component without harness connected

      (Front Lumbar Power Seat Switch)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      1 - 2 Hold switch pressed Below 1 Ω
      3 - 5
      1 - 2 Off
      2 - 3
      1 - 5 Release switch pressed
      2 - 3
      for RHD
      Tester Connection Condition Specified Condition
      1 - 5 Hold switch pressed Below 1 Ω
      2 - 3
      1 - 2 Off
      2 - 3
      1 - 2 Release switch pressed
      3 - 5

      If the result is not as specified, replace the front lumbar power seat switch.