PRE-COLLISION SYSTEM WARNING BUZZER INSPECTION

PROCEDURE


  1. INSPECT SKID CONTROL BUZZER


    1. A0022OU

      Make sure that there is no looseness at the locking part and the connecting part of the connector.

    2. Disconnect the skid control buzzer connector.

    3. Check both the connector case and the terminal for deformation and corrosion.

      OK
      No deformation or corrosion.
    4. Connect a positive (+) lead from the battery to terminal 2, and a negative (-) lead to terminal 1 of the skid control buzzer, and then check that the buzzer sounds.

      OK
      The skid control buzzer sounds.

      If the result is not as specified, replace the skid control buzzer.