AIRBAG SYSTEM SRS Warning Light does not Come ON

DESCRIPTION

The SRS warning light is located in the combination meter assembly.

When the SRS is normal, the SRS warning light comes on for approximately 6 seconds after the power switch is turned from off to on (IG), and then goes off automatically.

If there is a malfunction in the SRS, the SRS warning light comes on to inform the driver of a problem.

If a malfunction occurs in the airbag sensor assembly, combination meter assembly or wire harness connected to the airbag sensor assembly or combination meter assembly, the SRS warning light turns on.

When terminals TC and CG of the DLC3 are connected, DTCs are displayed by blinking of the SRS warning light.

The SRS is equipped with a voltage-increase circuit (DC-DC converter) in the airbag sensor assembly in case the source voltage drops.

When the auxiliary battery voltage drops, the voltage-increase circuit (DC-DC converter) functions to increase the voltage of the SRS to normal voltage.

A malfunction in this circuit is not stored in the airbag sensor assembly. The SRS warning light automatically goes off when the source voltage returns to normal.

The signal to illuminate the SRS warning light is transmitted from the airbag sensor assembly to the combination meter assembly via the CAN communication system.

WIRING DIAGRAM

B003XWWE10

CAUTION / NOTICE / HINT

Note


  • After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

    Click here

  • Inspect the fuses for circuits related to this system before performing the following procedure.

PROCEDURE


  1. CHECK AUXILIARY BATTERY VOLTAGE


    1. Measure the voltage of the auxiliary battery.

      Standard Voltage
      11 to 14 V
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK CONNECTOR


    1. Turn the power switch off.

    2. Disconnect the cable from the negative (-) auxiliary battery terminal.

      CAUTION:

      Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.

    3. Check that the connector is properly connected to the combination meter assembly.

      OK
      The connector is properly connected.

      Tech Tips

      If the connector is not properly connected, reconnect the connector and proceed to the next inspection.

    4. Disconnect the connector from the combination meter assembly.

    5. Check that the terminals of the connector are not damaged.

      OK
      The terminals are not deformed or damaged.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK WIRE HARNESS (COMBINATION METER ASSEMBLY - BODY GROUND)


    1. B003Y7PC07
      *a

      Front view of wire harness connector

      (to Combination Meter Assembly)

      Connect the cable to the negative (-) auxiliary battery terminal.

    2. Turn the power switch on (IG).

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      K3-21 (IG+) - Body ground Power switch on (IG) 11 to 14 V
      K3-22 (B) - Body ground Always 11 to 14 V
    4. Turn the power switch off.

    5. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      K3-31 (ES) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK SRS WARNING LIGHT


    1. Disconnect the cable from the negative (-) auxiliary battery terminal.

      CAUTION:

      Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.

    2. Connect the connector to the combination meter assembly.

    3. Disconnect the connector from the airbag sensor assembly.

    4. Connect the cable to the negative (-) auxiliary battery terminal.

    5. Turn the power switch on (IG) and check the SRS warning light condition.

      OK
      After the primary check period, the SRS warning light goes off for approximately 10 seconds and turns back on.

      Tech Tips

      The primary check period is approximately 6 seconds after the power switch is turned on (IG).

      Result
      Proceed to
      OK
      NG

    OK
    NG