CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
Disconnect the K10 air conditioning amplifier assembly connector.
Measure the voltage and resistance according to the value(s) in the table below.
Tech Tips
Measure the values on the wire harness side with the connector disconnected.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| K10-5 (IG+) - K10-1 (GND) | R - BR | Power source (IG) | Power switch on (IG) | 11 to 14 V |
| K10-5 (IG+) - K10-1 (GND) | R - BR | Power source (IG) | Power switch off | Below 1 V |
| K10-6 (+B1) - K10-1 (GND) | L - BR | Auxiliary battery power supply | Power switch off | 11 to 14 V |
| K10-1 (GND) - Body ground | BR - Body ground | Ground | Always | Below 1 Ω |
If the result is not as specified, there may be a malfunction in the wire harness.
Reconnect the K10 air conditioning amplifier assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| K10-24 (FDEF) - K10-1 (GND) | G - BR | Wiper Deicer signal | Power switch on (IG), Outer mirror heater switch assembly off | 11 to 14 V |
| K10-24 (FDEF) - K10-1 (GND) | G - BR | Wiper Deicer signal | Power switch on (IG), Outer mirror heater switch assembly on | Below 2.2 V |
| K10-17 (SWL2) - K10-1 (GND) | R - BR | Outer mirror heater switch assembly indicator signal | Power switch on (IG), Outer mirror heater switch assembly off | 11 to 14 V |
| K10-17 (SWL2) - K10-1 (GND) | R - BR | Outer mirror heater switch assembly indicator signal | Power switch on (IG), Outer mirror heater switch assembly on | Below 1 V |
| K11-28 (SW6) - K10-1 (GND) | V - BR | Outer mirror heater switch assembly signal | Power switch on (IG), Outer mirror heater switch assembly off | Below 1 V |
| K11-28 (SW6) - K10-1 (GND) | V - BR | Outer mirror heater switch assembly signal | Power switch on (IG), Outer mirror heater switch assembly on | 11 to 14 V |
If the result is not as specified, the air conditioning amplifier assembly may be malfunctioning.