2AR-FSE BATTERY / CHARGING SERVICE DATA

Auxiliary battery voltage Positive (+) terminal - Negative (-) terminal 20°C (68°F), Power switch off

12.5 V or higher

Auxiliary battery is OK

11.0 to 12.5 V

Recharge auxiliary battery

Below 11.0 V

Replace auxiliary battery

Recharge auxiliary battery S55D23R 4 to 5 A
Fuse Standard resistance Below 1 Ω
DC/ DC converter assembly Current flowing from auxiliary battery Auxiliary battery positive cable Power switch on (READY) (The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.)

0 A or less

(no current from auxiliary battery)

Auxiliary battery voltage Positive (+) terminal - Negative (-) terminal 13 to 15 V
Auxiliary battery thermometer sensor Standard Resistance 1 - 2 3.00 to 3.73 kΩ at 10°C (50°F)
2.45 to 2.88 kΩ at 15°C (59°F)
1.95 to 2.30 kΩ at 20°C (68°F)
1.60 to 1.80 kΩ at 25°C (77°F)
1.28 to 1.47 kΩ at 30°C (86°F)
1.00 to 1.22 kΩ at 35°C (95°F)
0.80 to 1.00 kΩ at 40°C (104°F)
0.65 to 0.85 kΩ at 45°C (113°F)
0.50 to 0.70 kΩ at 50°C (122°F)
0.44 to 0.60 kΩ at 55°C (131°F)
0.36 to 0.50 kΩ at 60°C (140°F)