2AR-FSE COOLING SERVICE DATA

THERMOSTAT
Condition Specified Condition
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 8.0 mm (0.315 in.) or more at 95°C (203°F)
COOLING FAN MOTOR
Item Condition Specified Condition
Cooling fan motor Battery voltage applied at 20°C (68°F) 13.0 to 19.0 A
No. 2 cooling fan motor Battery voltage applied at 20°C (68°F) 13.0 to 19.0 A
FAN RELAY
Item Tester Connection Specified Condition
Fan relay 3 - 5

10 kΩ or higher

(Battery voltage not applied between terminals 1 and 2)

3 - 5

Below 1 Ω

(Battery voltage applied between terminals 1 and 2)

RADIATOR
Item Condition Specified Condition
Radiator cap sub-assembly

Standard value

(for brand-new cap)

93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18 psi)

Minimum standard value

(for used cap)

79 kPa (0.8 kgf/cm2, 11.5 psi)

COOLANT
Capacity Classification
8.2 liters (8.7 US qts, 7.2 lmp. qts) Use only "TOYOTA Super Long Life Coolant", or similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, and non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of low phosphates and organic acids).