AIR CONDITIONING PRESSURE SENSOR INSTALLATION

PROCEDURE


  1. INSTALL AIR CONDITIONER PRESSURE SENSOR


    1. Remove the vinyl tape from the liquid tube sub-assembly A and the connecting part of the air conditioner pressure sensor.

    2. Sufficiently apply compressor oil to a new air conditioner pressure sensor and the fitting surface of the air conditioner pressure sensor.

      Refrigerant Compressor Oil
      HFC-134a (R134a) ND-OIL 8 or equivalent
      HFO-1234yf (R1234yf) ND-OIL 12 or equivalent
    3. A01MYY3C02
      *a Turn
      *b Hold

      Using a 27 mm deep socket wrench, install the air conditioner pressure sensor as shown in the illustration.

      Torque:
      10.8 N*m  { 110 kgf*cm, 8 ft.*lbf }
    4. Connect the connector.

  2. INSTALL LOW PITCHED HORN ASSEMBLY

    Click here

  3. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT (for HFC-134a(R134a))

    Click here

  4. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT (for HFO-1234yf(R1234yf))

    Click here

  5. WARM UP ENGINE (for HFC-134a(R134a))

    Click here

  6. WARM UP ENGINE (for HFO-1234yf(R1234yf))

    Click here

  7. INSPECT FOR REFRIGERANT LEAK (for HFC-134a(R134a))

    Click here

  8. INSPECT FOR REFRIGERANT LEAK (for HFO-1234yf(R1234yf))

    Click here