PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM (for HFC-134a(R134a))
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM (for HFO-1234yf(R1234yf))
REMOVE LOW PITCHED HORN ASSEMBLY
REMOVE AIR CONDITIONER PRESSURE SENSOR
Disconnect the connector.
| *a | Turn |
| *b | Hold |
Using a 27 mm deep socket wrench, remove the air conditioner pressure sensor as shown in the illustration.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.