AUTOMATIC TRANSMISSION SYSTEM(for 8AR-FTS), Diagnostic DTC:P271313

DTC Code DTC Name
P271313 Pressure Control Solenoid "D" Circuit Open

DESCRIPTION

Refer to DTC P27137F.

Click here

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P271313 Pressure Control Solenoid "D" Circuit Open

1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other


  1. Engine is running

  2. Solenoid (SLT) valve circuit is open or shorted

  3. 1 second

  4. 1-trip detection logic


  • Solenoid (SLT) valve

  • Transmission wire

  • Harness and connector

  • ECM

Comes on DTC stored

SAE Code:

P2716

MONITOR DESCRIPTION

When an open or short in the solenoid (SLT) valve circuit is detected, the ECM will determine that there is a malfunction, illuminate the MIL and store this DTC.

WIRING DIAGRAM

B003WT5E69
*a Solenoid (SLT) Valve
*b Transmission Wire

CAUTION / NOTICE / HINT

Note

Perform registration and/or initialization when parts related to the automatic transmission are replaced.

Click here

Tech Tips

After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.


  1. Start the engine.

  2. Check for DTCs again.

    Click here

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE (SOLENOID (SLT) VALVE) - ECM)


    1. Disconnect the F78 ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F78-1 (SLT+) - F78-31 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      F78-1 (SLT+) or F78-31 (SLT-) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. REPLACE ECM


    1. Replace the ECM.

      Click here

      Result
      Proceed to
      NEXT

    NEXT
  3. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    1. Disconnect the F73 transmission wire connector.

    2. Disconnect the F78 ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F73-22 (SLT+) - F78-1 (SLT+) Always Below 1 Ω
      F73-23 (SLT-) - F78-31 (SLT-) Always Below 1 Ω
      F73-22 (SLT+) or F78-1 (SLT+) - Body ground Always 10 kΩ or higher
      F73-23 (SLT-) or F78-31 (SLT-) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. INSPECT SOLENOID (SLT) VALVE


    1. B003VU8C46
      *a

      Component without harness connected

      (Solenoid (SLT) Valve)

      Remove the solenoid (SLT) valve.

      Click here

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Terminal 1 of the solenoid (SLT) valve - terminal 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Connect a positive (+) lead from the battery with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Check that the valve moves and makes an operating sound.

      OK
      Valve moves and makes an operating sound.
      Result
      Proceed to
      OK
      NG

    OK
    NG