VALVE BODY ASSEMBLY INSPECTION

PROCEDURE


  1. INSPECT SHIFT SOLENOID VALVE SL1


    1. B003VU8C48
      *a

      Component without harness connected

      (Shift Solenoid Valve SL1)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Connect the positive (+) lead with a 21 W bulb to terminal 1 and the negative (-) lead to terminal 2 of the shift solenoid valve SL1 connector, then check the movement of the shift solenoid valve SL1.

      OK
      The solenoid makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve SL1.

  2. INSPECT SHIFT SOLENOID VALVE SL2


    1. B003VU8C48
      *a

      Component without harness connected

      (Shift Solenoid Valve SL2)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Connect the positive (+) lead with a 21 W bulb to terminal 1 and the negative (-) lead to terminal 2 of the shift solenoid valve SL2 connector, then check the movement of the shift solenoid valve SL2.

      OK
      The solenoid makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve SL2.

  3. INSPECT SHIFT SOLENOID VALVE S1


    1. A01MWH8C01
      *a

      Component without harness connected

      (Shift Solenoid Valve S1)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body 15 to 25 °C (59 to 77 °F) 11 to 15 Ω
    2. Connect the positive (+) lead to the terminal of the shift solenoid valve connector, and the negative (-) lead to the shift solenoid valve S1 body.

      OK
      The solenoid makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve S1.

  4. INSPECT SHIFT SOLENOID VALVE S3


    1. A01MWH8C01
      *a

      Component without harness connected

      (Shift Solenoid Valve S3)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve S3 connector terminal - Shift solenoid valve S3 body 15 to 25 °C (59 to 77 °F) 11 to 15 Ω
    2. Connect the positive (+) lead to the terminal of the shift solenoid valve connector, and the negative (-) lead to the shift solenoid valve S3 body.

      OK
      The solenoid makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve S3.

  5. INSPECT SHIFT SOLENOID VALVE S2


    1. A01MUUGC05
      *a

      Component without harness connected

      (Shift Solenoid Valve S2)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body 15 to 25 °C (59 to 77 °F) 11 to 15 Ω
    2. Connect the positive (+) lead to the terminal of the shift solenoid valve S2 connector, and the negative (-) lead to the shift solenoid valve S2 body.

      OK
      The solenoid makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve S2.

  6. INSPECT SHIFT SOLENOID VALVE S4


    1. A01MXWKC04
      *a

      Component without harness connected

      (Shift Solenoid Valve S4)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve S4 connector terminal - Shift solenoid valve S4 body 15 to 25 °C (59 to 77 °F) 11 to 15 Ω
    2. Connect the positive (+) lead to the terminal of the shift solenoid valve S4 connector, and the negative (-) lead to the shift solenoid valve S4 body.

      OK
      The solenoid makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve S4.

  7. INSPECT SHIFT SOLENOID VALVE SR


    1. A01MVB1C04
      *a

      Component without harness connected

      (Shift Solenoid Valve SR)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve SR connector terminal - Shift solenoid valve SR body 15 to 25 °C (59 to 77 °F) 11 to 15 Ω
    2. Connect the positive (+) lead to the terminal of the shift solenoid valve SR connector, and the negative (-) lead to the shift solenoid valve SR body.

      OK
      The solenoid makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve SR.

  8. INSPECT SHIFT SOLENOID VALVE SLT


    1. A01MYNLC47
      *a

      Component without harness connected

      (Shift Solenoid Valve SLT)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20 °C (68 °F) 5.0 to 5.6 Ω
    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the shift solenoid valve SLT connector, then check the movement of the valve.

      OK
      The solenoid makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve SLT.

  9. INSPECT SHIFT SOLENOID VALVE SLU


    1. A01MYNLC48
      *a

      Component without harness connected

      (Shift Solenoid Valve SLU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20 °C (68 °F) 5.0 to 5.6 Ω
    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the shift solenoid valve SLU connector, then check the movement of the valve.

      OK
      The solenoid makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve SLU.