PROCEDURE
INSPECT TRANSMISSION REVOLUTION SENSOR (NT)
| *a | Component without harness connected (Transmission Revolution Sensor (NT)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 560 to 680 Ω |
If the result is not as specified, replace the transmission revolution sensor (NT).
INSPECT TRANSMISSION REVOLUTION SENSOR (SP2)
| *a | Component without harness connected (Transmission Revolution Sensor (SP2)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 560 to 680 Ω |
If the result is not as specified, replace the transmission revolution sensor (SP2).