PROCEDURE
INSTALL ELECTROMAGNETIC OIL PUMP (w/ Stop And Start System)
Coat the O-ring of the electromagnetic oil pump with ATF.
Install the electromagnetic oil pump to the transmission valve body assembly with the bolt.
Note
When reusing the electromagnetic oil pump, inspect the O-ring.
Make sure that the O-ring is not cracked or jammed when installing the electromagnetic oil pump.
INSTALL SOLENOID (SL5) VALVE
Install the solenoid (SL5) valve.
Install the straight pin.
INSTALL SOLENOID (SL3) VALVE
Install the solenoid (SL3) valve.
Install the straight pin.
INSTALL SOLENOID (SL4) VALVE
Install the solenoid (SL4) valve.
Install the straight pin.
INSTALL SOLENOID (SL2) VALVE
Install the solenoid (SL2) valve.
Install the straight pin.
INSTALL SOLENOID (SL1) VALVE
Install the solenoid (SL1) valve.
Install the straight pin.
INSTALL SOLENOID (SLT) VALVE
Install the solenoid (SLT) valve.
Install the straight pin.
INSTALL SOLENOID (SLU) VALVE
Install the solenoid (SLU) valve.
Install the straight pin.
INSTALL SOLENOID LOCK PLATE
Install the solenoid lock plate with the 3 bolts.
INSTALL SOLENOID (SC2) VALVE
Install the solenoid (SC2) valve with the bolt.
INSTALL SOLENOID (SC1) VALVE
Install the solenoid (SC1) valve with the bolt.