PROCEDURE
CHECK COOLING FAN MOTOR
| *a | Component without harness connected (Cooling Fan Motor) |
for Cooling Fan Motor 160 W + 160 W Type or 200 W + 200 W Type:
Disconnect the cooling fan motor connector.
Check that the cooling fan motor operates smoothly when the battery is connected to the cooling fan motor connector.
Measure the current while the cooling fan motor is operating.
| Standard Current | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Connect the cooling fan motor connector.
| *a | Component without harness connected (Cooling Fan Motor) |
for Cooling Fan Motor 240 W + 240 W Type:
Disconnect the cooling fan motor connector.
Check that the cooling fan motor operates smoothly when the battery is connected to the cooling fan motor connector.
Measure the current while the cooling fan motor is operating.
| Standard Current | ||||
|---|---|---|---|---|
|
Connect the cooling fan motor connector.
CHECK NO. 2 COOLING FAN MOTOR
Disconnect the No. 2 cooling fan motor connector.
| *a | Component without harness connected (No. 2 Cooling Fan Motor) |
Check that the No. 2 cooling fan motor operates smoothly when the battery is connected to the No. 2 cooling fan motor connector.
Measure the current while the No. 2 cooling fan motor is operating.
| Standard Current | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 2 cooling fan motor.
Connect the No. 2 cooling fan motor connector.