WASTE GATE VALVE ACTUATOR INSTALLATION

PROCEDURE


  1. INSTALL WASTE GATE VALVE ACTUATOR WITH BRACKET ASSEMBLY

    Note

    After removal and installation of the waste gate valve actuator with bracket assembly, make sure to check the travel of the waste gate valve actuator.


    1. Install the waste gate valve actuator with bracket assembly to the compressor housing with bearing sub-assembly with the 2 bolts.

      Torque:
      24 N*m  { 245 kgf*cm, 18 ft.*lbf }

      Tech Tips

      If 2 adjustment washers are installed between the waste gate valve actuator with bracket assembly and compressor housing with bearing sub-assembly, install the washers to their original locations.

    2. Install a new E-washer to the waste gate valve actuator with bracket assembly link pin.

      Note

      Do not reuse the E-washer.

  2. INSPECT WASTE GATE VALVE ACTUATOR WITH BRACKET ASSEMBLY

    Click here

  3. INSTALL INLET COMPRESSOR ELBOW


    1. Install a new inlet compressor gasket to the turbocharger sub-assembly.

    2. Install the inlet compressor elbow to the turbocharger sub-assembly with the 2 nuts.

      Torque:
      24 N*m  { 245 kgf*cm, 18 ft.*lbf }
    3. Engage the clamp.

  4. INSTALL EXHAUST MANIFOLD CONVERTER SUB-ASSEMBLY (TWC: Front and Rear Catalyst)

    Click here