STARTER INSTALLATION

PROCEDURE


  1. INSTALL STARTER ASSEMBLY


    1. Install the starter assembly with the 2 bolts.

      Torque:
      46 N*m  { 469 kgf*cm, 34 ft.*lbf }
    2. Connect the wire harness, install the nut and close the terminal cap.

      Torque:
      9.8 N*m  { 100 kgf*cm, 87 in.*lbf }
    3. Connect the starter connector.

  2. INSTALL STARTER COVER


    1. Install the starter cover with the 2 bolts.

      Torque:
      11.5 N*m  { 117 kgf*cm, 8 ft.*lbf }
  3. INSTALL EXHAUST MANIFOLD SUB-ASSEMBLY LH (TWC: Front Catalyst)

    Click here

  4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.