VACUUM REGULATING VALVE INSTALLATION

PROCEDURE


  1. INSTALL VACUUM REGULATING VALVE ASSEMBLY


    1. Install the vacuum regulating valve assembly to the intake manifold with the 2 bolts.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
    2. Connect the vacuum transmitting hose assembly and No. 3 vacuum transmitting hose assembly to the vacuum regulating valve assembly.

    3. Connect the vacuum regulating valve assembly connector.