COLD START INJECTOR INSPECTION

PROCEDURE


  1. INSPECT COLD START FUEL INJECTOR ASSEMBLY


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 1.5 to 6.5 Ω

      If the result is not as specified, replace the cold start fuel injector assembly.