ГЕНЕРАТОР ПРОВЕРКА

PROCEDURE


  1. INSPECT BRUSH


    1. A01QOW7C03
      *a Exposed Length

      Using a vernier caliper, measure the length of the exposed brushes.

      Standard exposed length
      11.2 mm (0.441 in.)
      Minimum exposed length
      2.0 mm (0.0787 in.)

      If the exposed length is less than the minimum, replace the generator regulator assembly.