ПОДОГРЕВАЕМЫЙ КИСЛОРОДНЫЙ ДАТЧИК УСТАНОВКА

PROCEDURE


  1. INSTALL HEATED OXYGEN SENSOR


    1. for Bank 2:


      1. A01MV05C01
        *a Length of SST 30 mm (1.18 in.)
        *b Length of Torque Wrench 260 mm (10.2 in.)

        Using SST, install the heated oxygen sensor to the front exhaust pipe assembly.

        SST
        09224-00010
        Torque:
        without SST [Torque (N*m (kgf*cm, ft.*lbf))]
        44 N*m  { 449 kgf*cm, 32 ft.*lbf }
        with SST [Reading of Torque wrench (N*m (kgf*cm, ft.*lbf))]
        39 N*m  { 398 kgf*cm, 29 ft.*lbf }

        Note

        If a heated oxygen sensor has been struck or dropped, replace it.

        Tech Tips


        • This torque value is effective when SST is parallel to the torque wrench.

        • The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).

        • The "with SST" torque value is effective when using a torque wrench with a fulcrum length of 260 mm (10.2 in.).

        • If using a torque wrench with a different length, or connecting the torque wrench and SST at an angle, refer to the alternate torque values.

          Click here

      2. Install the heated oxygen sensor grommet to the body.

    2. for Bank 1:


      1. A01MW3CC01
        *a Length of SST 30 mm (1.18 in.)
        *b Length of Torque Wrench 260 mm (10.2 in.)

        Using SST, install the heated oxygen sensor to the front exhaust pipe assembly.

        SST
        09224-00010
        Torque:
        without SST [Torque (N*m (kgf*cm, ft.*lbf))]
        44 N*m  { 449 kgf*cm, 32 ft.*lbf }
        with SST [Reading of Torque wrench (N*m (kgf*cm, ft.*lbf))]
        39 N*m  { 398 kgf*cm, 29 ft.*lbf }

        Note

        If a heated oxygen sensor has been struck or dropped, replace it.

        Tech Tips


        • This torque value is effective when SST is parallel to the torque wrench.

        • The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).

        • The "with SST" torque value is effective when using a torque wrench with a fulcrum length of 260 mm (10.2 in.).

        • If using a torque wrench with a different length, or connecting the torque wrench and SST at an angle, refer to the alternate torque values.

          Click here

      2. Install the heated oxygen sensor grommet to the body.

  2. CONNECT HEATED OXYGEN SENSOR CONNECTOR


    1. for Bank 2:


      1. w/ Clamp:


        1. Connect the clamp.

      2. Connect the heated oxygen sensor connector.

      3. Install the floor carpet.

    2. for Bank 1:


      1. w/ Clamp:


        1. Connect the clamp.

      2. Connect the heated oxygen sensor connector.

      3. Install the floor carpet.

  3. INSTALL CONSOLE BOX ASSEMBLY

    Click here

  4. INSPECT FOR EXHAUST GAS LEAK

    Click here