ECM УСТАНОВКА

PROCEDURE


  1. INSTALL NO. 2 ECM BRACKET


    1. Install the No. 2 ECM bracket to the ECM with the 2 screws.

      Torque:
      3.0 N*m  { 31 kgf*cm, 27 in.*lbf }
  2. INSTALL NO. 1 ECM BRACKET


    1. Install the No. 1 ECM bracket to the ECM with the 2 screws.

      Torque:
      3.0 N*m  { 31 kgf*cm, 27 in.*lbf }
  3. INSTALL ECM


    1. Install the ECM to the engine room ECU box with the 2 nuts.

      Torque:
      5.5 N*m  { 56 kgf*cm, 49 in.*lbf }

      Note


      • Install the ECM to the engine room ECU box with the name plate facing the outside of the vehicle.

      • When connecting the connectors, make sure that dirt, water or other foreign matter does not become stuck between the connectors and other part.

      • If the ECM has been struck or dropped, replace it.

  4. CONNECT WIRE HARNESS


    1. Connect the 6 ECM connectors.

      Note

      Be sure to securely connect the ECM connector.

    2. Engage the claw to connect the connector holder to the engine room ECU box.

    3. A01MXV7

      Connect the connector to the connector holder.

    4. Connect the 2 engine wire harness connectors to the connector holder.

  5. INSTALL ENGINE ROOM ECU COVER


    1. Install the engine room ECU cover with the 3 bolts.

      Torque:
      5.5 N*m  { 56 kgf*cm, 49 in.*lbf }

      Note

      Make sure that the wire harness does not get caught between the parts.

  6. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  7. PERFORM INITIALIZATION

    Click here