HAZARD WARNING SWITCH INSPECTION

PROCEDURE


  1. INSPECT TELLTALE LIGHT ASSEMBLY (HAZARD WARNING SWITCH)


    1. A00YWI6C01
      *a

      Component without harness connected

      (Telltale Light Assembly (Hazard Warning Switch))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      7 (TB) - 13 (E) Hazard warning signal switch off 10 kΩ or higher
      Hazard warning signal switch on Below 1 Ω

      If the result is not as specified, replace the telltale light assembly (hazard warning switch).