ECO SWITCH INSPECTION

PROCEDURE


  1. INSPECT COMBINATION SWITCH ASSEMBLY (ECO SWITCH)


    1. A00YS7FC01
      *a

      Component without harness connected

      (Combination Switch Assembly (ECO Switch))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      G60-3 (LCC) - G60-4 (EEF) ECO MODE switch is pushed Below 1 Ω
      G60-3 (LCC) - G60-4 (EEF) ECO MODE switch is not pushed 1 MΩ or higher

      If the result is not as specified, replace the combination switch assembly (ECO switch).