REFRIGERANT LINE REMOVAL

PROCEDURE


  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM


    1. for HFC-134a (R134a):

      Click here

    2. for HFO-1234yf (R1234yf):

      Click here

  2. REMOVE PIPING CLAMP


    1. A01V777C02
      *1 Suction Pipe Sub-assembly
      *2 Liquid Tube Sub-assembly

      Install SST to the piping clamp as shown in the illustration.

      SST
      09870-00025
    2. A01V8CQC02
      *a Push in

      Hold the liquid tube sub-assembly and suction pipe sub-assembly with each hand and push in SST with both thumbs.

      Note

      Do not apply excessive force to the liquid tube sub-assembly or suction pipe sub-assembly as they may bend.

    3. A01V8R9C02
      *1 Suction Pipe Sub-assembly
      *a Stopper
      *b Pull off

      Raise the stopper of SST and remove SST and the piping clamp together from the suction pipe sub-assembly.

    4. Remove the piping clamp from SST.

    5. Remove the liquid tube sub-assembly from the suction pipe sub-assembly.

    6. Remove the 2 O-rings from the liquid tube sub-assembly.

      Note

      Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.