PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
for HFC-134a (R134a):
for HFO-1234yf (R1234yf):
REMOVE PIPING CLAMP
| *1 | Suction Pipe Sub-assembly |
| *2 | Liquid Tube Sub-assembly |
Install SST to the piping clamp as shown in the illustration.
| *a | Push in |
Hold the liquid tube sub-assembly and suction pipe sub-assembly with each hand and push in SST with both thumbs.
Note
Do not apply excessive force to the liquid tube sub-assembly or suction pipe sub-assembly as they may bend.
| *1 | Suction Pipe Sub-assembly |
| *a | Stopper |
| *b | Pull off |
Raise the stopper of SST and remove SST and the piping clamp together from the suction pipe sub-assembly.
Remove the piping clamp from SST.
Remove the liquid tube sub-assembly from the suction pipe sub-assembly.
Remove the 2 O-rings from the liquid tube sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.