| DTC Code | DTC Name |
|---|---|
| B1411/11 | Room Temperature Sensor Circuit |
DESCRIPTION
The cooler (room temperature sensor) thermistor is installed in the instrument panel to detect the cabin temperature which is used to control the heater and air conditioning system AUTO mode. The resistance of the cooler (room temperature sensor) thermistor changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies a voltage (5 V) to the cooler (room temperature sensor) thermistor and reads voltage changes due to changes in the resistance of the cooler (room temperature sensor) thermistor.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | Note |
|---|---|---|---|---|---|
| B1411/11 | Room Temperature Sensor Circuit | Open or short in cooler (room temperature sensor) thermistor circuit |
|
Memorized (4 seconds or more) | - |
Tech Tips
The air conditioning amplifier assembly stores the DTC of the respective malfunction if it has occurred for the period of time indicated in the brackets.
If the cabin temperature is approximately -18.6°C (-1.48°F) or less, DTC B1411/11 may be output even though the system is normal.
WIRING DIAGRAM
| *a | Cooler (Room Temperature Sensor) Thermistor |
| *b | Air Conditioning Amplifier Assembly |
CAUTION / NOTICE / HINT
Note
When the battery is disconnected or the air conditioning amplifier assembly is replaced, be sure to perform servo motor initialization
PROCEDURE
READ VALUE USING GTS
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Room Temperature Sensor | Cooler thermistor (room temperature sensor) | Min.: -6.50°C (20.30°F) Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | - |
| Tester Display |
|---|
| Room Temperature Sensor |
| OK |
|---|
| The display is as specified in the normal condition column. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| A |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| B |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| C |
|
INSPECT COOLER (ROOM TEMPERATURE SENSOR) THERMISTOR
Remove the cooler (room temperature sensor) thermistor.
Inspect the cooler (room temperature sensor) thermistor.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE COOLER (ROOM TEMPERATURE SENSOR) THERMISTOR Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - COOLER [ROOM TEMPERATURE SENSOR] THERMISTOR)
Disconnect the G81 air conditioning amplifier assembly connector.
Disconnect the G19 cooler (room temperature sensor) thermistor connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |